Environmental Simulation Equipment

QS-DT-CF-1000 Standard Dustproof Test Box

Word:[Big][Middle][Small] Mobile page qrcode 2024/3/13     Viewed:    




Dustproofing test for all kinds of prototypes


Adaptation standards


IEC 60529, IP5X/6X


GB/T 4208, IP5X/6X


ISO 20653, IP5X/6X


GB/T 30038, IP5X/6X


IEC 60068-2-68, La2


GB/T 2423.37, La2


JIS D 0207


IEC 60598-1, IP5X/6X

GB 7000.1, IP5X/6X

GB/T 10485, 防尘试验

IEC 60034-5, IP5X/6X

GB/T 4942.1, IP5X/6X

SAE J 575, Dust Exposure Test


Specificities

- The inner liner of the test chamber is made of high-quality, corrosion-resistant

stainlesssteel with frequency conversion to control the air flow rate inside the

chamber.
- The door frame is double sealed to avoid dust leakage.
- Large viewing window for observation of sample parts
- Dust filter for exhaust port
- Vacuum system for test specimens
- Multi-safety protection
- 15" color touch screen with menu interface
- Test data curve display
- USB interface for automatic data recording via USB flash drive
- Ethernet interface for remote monitoring and control


     

System design and description



- The blower is used to realize the circulation of talcum powder in the box.
- The blower is controlled by a frequency converter, which can be set at different frequencies to achieve different air speeds.
- The dust entering the blower is pre-screened.
- A vibrator is used to vibrate the dust scattered on the walls of the chamber down to the screen.
- According to the test requirements into the appropriate amount of dust, not more than 4kg
- The equipment is equipped with a sample pumping system, when you need to use the sample in the box and the pumping interface connected to the negative pressure.
- The pumping system consists of a vacuum pump, a dust filter, a differential pressure sensor, an air flow meter and a flow control valve.
- After calculating the pumping flow rate according to the test requirements, the required flow rate can be achieved by adjusting the flow regulating valve.



- By blowing air or fan (blowing air is used in this unit), the dust is lifted up at regular intervals and distributed evenly in the box.
- Different levels of dust concentration can be realized by setting different blowing pressures.
- The test temperature is 20℃±15℃ and the test humidity is 45% RH~85% RH.
- There is a heating plate attached to the wall of the box, and the temperature inside the box can be set to achieve the appropriate temperature and humidity.
- Temperature and humidity sensors are installed inside the chamber to collect the temperature and relative humidity.


系统参数与操作



① The main signals and alarm triggers of the equipment are displayed, such as gas source pressure, phase sequence of power supply and door signal.

② test chamber set temperature, real-time temperature and real-time humidity curve display

③ Digital display of test chamber set temperature, real-time temperature, real-time humidity and wind speed.

④ Display of operation mode, relative pressure and flow rate of vacuum circuit

⑤ Timing display of vibration cycle and dust blowing cycle.

 ⑥ Display of test progress

⑦ Equipment operation information prompts

⑧ Protective operation and stop touch keys, each operation needs to be confirmed.





①Test Chamber Temperature Setting

② Operation mode selection: C1/C2/C3

③ Wind speed setting: max. 25m/s

④ Test total time setting, maximum value 99999 hours

⑤ Vibration cycle and time setting

⑥ Dust blowing cycle time setting

⑦ If equipped with serial port communication, you can set the communication baud rate and node number.

⑧ Each parameter modification needs to be saved before taking effect.



Design and technical parameters





Go Back
Print
021-39591801
138-1768-2419(Mr. Yan)
Wechat QR code